User Instruction Manual

Pagina 2 - CAUTION:

10CAUTION: Replacing the battery will not delete meter settings or test results stored in the meter unless you:•Touchthemetalportiononmainunit

Pagina 3 - TABLE OF CONTENTS

11To replace battery:1. Turn meter off.2. Remove the battery cover on the back of the meter.3. Slide the battery to the right (a) and remove it (b)

Pagina 4

125. Replace battery cover.If the clock setting has been deleted, SET will appear on the screen. If SET appears, set the time and date. If you do not

Pagina 5 - INTRODUCTION

13Changing the Colored FaceplatesThe GLUCOCARD™ 01-mini comes with multiple interchangeable colored faceplates. You can attach the color of your choic

Pagina 6 - The System Includes:

4. Hook the end of the display cover into the holeof your preferred color faceplate.5. Fit one of the tabs on the display cover into thecorresponding

Pagina 7 - 01-mini BLOOD GLUCOSE METER

Meter set-up allows you to adjust the audible beep volume and to set time, date, and test averaging. Before using the GLUCOCARD™ 01-mini blood glucose

Pagina 8

16Setup mode Audible BeepSee page 18.Date and timeSee page 20.Test average displaySee page 23.EndPress the button to follow the black arrows.To

Pagina 9 - GLUCOCARD™ 01-SENSOR

Step 2: Press the and buttons at the same time for 5 seconds. A beep sounds and the meter turns on. Next, a second beep sounds and “SET” s

Pagina 10 - Changing the Battery

18Setting the Audible BeepIf the audible beep is turned “on”, the beep will sound when:•Youinsertateststripintothemeter.•Youapplybloodor

Pagina 11 - finger or any metal

19Press the button to cycle through the volume levels: “OFF” (no sound) “on 1” (low) “on 2”(middle) “on 3” (high) “OFF” (no sound) …, et

Pagina 12 - January 1, 2008, 12:00 a.m

CAUTION: Before using any product to test your blood sugar (blood glucose), read all instructions and practice the test. Do all quality control checks

Pagina 13

20Setting the YearIn the year set-up screen, the last two digits of the currently set year appear at the top of the screen. “yEr” appears in the middl

Pagina 14

21Setting the MonthPress the button to change the month. After you set the month, press the button to confirm the setting. The screen changes

Pagina 15 - METER SET-UP

22Setting the HourPress the button to change the hour. After you set the hour, press the button to confirm the setting. The screen changes to

Pagina 16 - Audible Beep

23NOTE: “Lo” results are included as 20 mg/dL in the averages. “Hi” results are included as 600 mg/dL in the averages. Test results with the following

Pagina 17 - Step 1: Turn off meter

24Ending Set-up To make further changes to set-up settings, press the button while “End” is displayed. This will bring up the Audible Beep set-u

Pagina 18 - Setting the Audible Beep

25Use GLUCOCARD™ 01 CONTROL to check if:•themeterandteststripsareworkingcorrectlyasasystem.•youaretestingcorrectly.Call your local sup

Pagina 19

26Perform a Control Solution Test:•BeforetestingwiththeGLUCOCARD™01-minibloodglucosemeter for the first time.•Whenyouopenanewbottle

Pagina 20 - Setting the Year

27•GLUCOCARD™01CONTROLisnotintendedforhuman   consumption. Do not drink.•Donotapplytoeye.Contactyourhealthcareprofessional 

Pagina 21 - Setting the Day

28Step 1: Insert a test strip as shown in diagram. Test strip should seat firmly into meter. The meter will turn on automatically. The full screen will

Pagina 22 - Setting the Minute

29Step 2: Press the button to enter the control mode. You will see “CONT” on the upper left of the screen. A “CONT” flag can also be attached when

Pagina 23 - Setting Test Average Display

Introduction ...5 Intended Use ...6 Understanding the GLUCOCARD™ 01-mini

Pagina 24 - Ending Set-up

30Step 3: Remove the cap from the control solution bottle. While the Apply Blood symbol and Code No. (F-2, F-3 or F-4) are alternating, place a ve

Pagina 25

31NOTE: Control solution test results are not included in the averages.Do not use the system if control solution result is out of range. See Troublesh

Pagina 26 - Important:

Troubleshooting Control Solution TestIf the control solution test result is out-of-range, check the following and repeat the test: Check Action Did

Pagina 27

33 Check Action Did you insert test strip Make sure test strip is inserted firmly into meter? all the way into test strip port. See diagra

Pagina 28 - Insert a test strip as shown

34Does your Control Solution result still read outside the range printed on the test strip bottle? If yes, the system may not be working correctly. DO

Pagina 29 - You will see

35The Multi-Lancet Device™NOTE: Do not use the lancet if the cap is missing or damaged.BLOOD GLUCOSE TESTINGMultilet (lancet)Disposal-and-set leverRem

Pagina 30

36Step 3: Twist off the protective cap.Step 4: Attach the removable cap.Step 2: Insert a new, unused lancet into the Holder until it stops.Holder

Pagina 31

37Step 5: The Multi-Lancet Device™ offers 7 different levels of skin penetration. For soft or thin skin or first time use, select “1 or 2.” For alterna

Pagina 32 - Check Action

38Step 4: Press the removable cap to the side of the fingertip. Press the lancing device button.Getting a Drop of BloodStep 1: Wash hands with soap and

Pagina 33

39Step 5: Set aside the Multi-Lancet Device™ and wait a few seconds for a blood drop to form. Keeping the hand warm, lowering the hand to waist level

Pagina 34

Blood Glucose Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 The Lancing Device ...

Pagina 35 - BLOOD GLUCOSE TESTING

40Performing a Blood Glucose TestStep 1: Remove test strip from the bottle. Immediately replace the bottle cap tightly. Insert test strip as shown in

Pagina 36 - Holder until it stops

41Step 2: The last test result will then appear. The Apply Blood symbol and the code number (F-2, F-3, or F-4) will alternate on the screen. Verif

Pagina 37 - 1 2 3 4 5 6 7

42Step 3: Obtain a blood drop (see pages 38-39). Apply blood to the end of the test strip. Capillary action will pull the blood into the strip. The me

Pagina 38 - Getting a Drop of Blood

43If it takes longer than 20 seconds to obtain a blood sample and to touch the test strip to the blood drop, repeat Step 3.Step 4: The meter will coun

Pagina 39

44Flagging Test ResultsFlags help you categorize and identify results. They can be used to omit specific results from result average calculations. You

Pagina 40

45Step 2: When you have selected the desired marker, remove the test strip. When you recall the result from memory, the selected marker will be displa

Pagina 41 - Expiration date

46Important Information About AST: Sites other than your fingertip may have fewer nerve endings so obtaining a blood sample from these sites may be les

Pagina 42 - Step 3: Obtain a blood drop

47Use Fingertip Testing: •Withintwohoursafterameal. •Withintwohoursafterinsulindosing. •Withintwohoursafterphysicalactivity. •I

Pagina 43

48Preparing to Test Your Blood Glucose From an Alternate SiteChoose a Site: Select a soft, fleshy area on the palm that is free of visible veins and mo

Pagina 44 - Flagging Test Results

49Prepare Your Lancing Device: To order an AST Lancing Kit containing the lancing device, lancets and instructions, please call 800.566.8558.Step 1:In

Pagina 45

Thank you for choosing the GLUCOCARD™ 01-mini Blood Glucose Monitoring System. This system measures blood glucose in fresh capillary whole blood. Resu

Pagina 46 - ALTERNATE SITE TESTING (AST)

Verify that the code number displayed on the screen matches the code number on the bottle of test strips used. If the code number does not match, the

Pagina 47 - Use Fingertip Testing:

51Step 3:a) PRESS AND VIGOROUSLY RUB THE SELECTED AREA for 10 seconds until it starts to feel warm to the touch.b) Firmly hold the cocked lancing devi

Pagina 48 - From an Alternate Site

52c) Press the release button on the lancing device to lance the skin. Continue to hold the lancing device firmly against the skin until a blood drop f

Pagina 49 - Insert lancet and

53IMPORTANT•Wasthesamplefreeofclearorwateryuid?•Wasthedroplargeenough(atleast0.3µL)?•Didthereactionsitellwithenoughblooda

Pagina 50 - Insert test strip as

54If the repeated alternate site result is still not consistent with how you feel, confirm your blood glucose level with fingertip testing.Step 6: Alway

Pagina 51 - until it

55The GLUCOCARD™ 01-mini blood glucose meter is referenced to a fresh plasma sample. Your meter results may differ from clinical lab results. This is

Pagina 52 - IMPORTANT

56ALWAYS wash hands with warm soapy water. Rinse and dry them before testing. ALWAYS use fresh capillary whole blood on meter tests.You may still see

Pagina 53 - Not Filled

57Normal Blood Glucose ReadingsExpected blood glucose levels for adults without diabetes¹,²: Fasting 70 to 110 mg/dL 1 to 2 hours after meals &l

Pagina 54

58Low Blood Glucose ReadingsIf your blood glucose is below 20 mg/dL, you will receive a “Lo.” Repeat the test with a new test strip. If this message s

Pagina 55 - UNDERSTANDING TEST RESULTS

59What This Means For You Frequent blood glucose testing is the best means to track how well you are doing with your diabetes management. It helps you

Pagina 56

6Intended UseThe GLUCOCARD™ 01-mini Blood Glucose Monitoring System is intended for the quantitative measurement of glucose in fresh capillary whole b

Pagina 57 - High Blood Glucose Readings

60The GLUCOCARD™ 01-mini blood glucose meter stores up to 50 test results. When more than 50 test results have been performed, the meter drops the old

Pagina 58 - Diabetes Findings

61•IfTestAveraginghasbeenturnedon,the average result will appear first.•IfTestAveraginghasbeensetto“Off”,the display will briefly

Pagina 59 - References

62Step 3: After all test results have been reviewed, “End” appears. •Pressthebuttononcetogobacktotherstresultinmemory.  You c

Pagina 60 - Press the button

63Step 2: Hold down the button for 2 seconds to display the most recent test result. If you have turned the result average display on, the resul

Pagina 61

64 CleaningTo prevent malfunction of the meter, keep the test strip port free of blood, moisture, dirt, or dust. Use a lint-free cloth dampened with w

Pagina 62 - Make sure meter is off

65Storage and Handling•Storemeterat32°F-122°F(0°C-50°C).•Donotleavethemeterinveryhotorcoldplaces.Donotleaveit  near a heat s

Pagina 63

66Display Screen and Error MessagesPlease first read this section. If you still have questions, call Customer Service at 800.566.8558 (24 hours a day,

Pagina 64 - MAINTENANCE

67Your blood glucose level is less than 20 mg/dL or there was not enough blood on test strip. Repeat test with new test strip. Make sure you use enoug

Pagina 65 - Storage and Handling

68The battery power is too low for testing. Test results and changes are not stored in the memory. Change the battery. See “Changing the battery” page

Pagina 66

69Test strip problem. Contact bars on test strip may be dirty. Incorrect test strip used. Used test strip has been inserted. Repeat test with new test

Pagina 67

7UNDERSTANDING THE GLUCOCARD™ 01-mini BLOOD GLUCOSE METERBottomTest Strip PortTopDisplayButton(1)Battery CoverStrap HoleButton(2)

Pagina 68

70Apply Control Solution. The Apply Blood symbol flashes alternately with the strip code number (F-2, F-3, or F-4) and “CONT” appears at the top of the

Pagina 69

71Product SpecificationsTest Strips: GLUCOCARD™ 01-SENSOR.Result Range: 20-600 mg/dL .Calibration: Plasma referenced.Sample Size: Minimum 0

Pagina 70

72Warnings, Precautions & Limitations•Youmaygettestresultshigherthanyouractualglucoselevel  if taking PAM (1-Methylpyridine-6-carba

Pagina 71 - PRODUCT INFORMATION

73•Extremesinhematocritmayaffecttestresults.Hematocritlevels  less than 30% may cause falsely high readings. Hematocrit levels grea

Pagina 72

74•TheGLUCOCARD™01-miniBloodGlucoseMonitoringSystemisnot designed to be a substitute for pathology laboratory equipment and should not

Pagina 73

75WarrantyYou are a valued customer of ARKRAY. It is important to us that you are completely satisfied with your GLUCOCARD™ 01-mini blood glucose meter

Pagina 74

76ReturnsYou must contact ARKRAY Customer Service at 800.566.8558 before returning your meter. You will be instructed how to return the meter to ARKRA

Pagina 75 - Warranty

Memory symbol:Shows you a past result in the memory.Appears when you are setting the date or time or reviewing a past result.Delete flagControl test f

Pagina 76 - FAX 952.646.3110

9GLUCOCARD™ 01-SENSORThese test strips need only 0.3 µL (microliter) of blood. Apply blood to the sample application tip. The strip draws in the blood